VULKAN LOKRING OEM
 

​​​​​​​​​Assembly​


​​

 
Slide the LOKRING over the inner tube so that the chamfer faces towards the tube end to be joined. Move the inner tube int​o the outer tube to at least “the length of the LOKRING + 3 mm” (in cases
i​nvolving flared tubes, it should be up to the stop) and apply LOKPREP between the mated tubes. Place the tool in such a way that the clamping jaws are positioned on the side of the outer tube and the LOKRING can be pushed to the end of the outer tube.

​​​
​​

​​​
 
Following the actuation of the push button, the outer tube is clamped by the clamping jaws and the LOKRING is pushed over the outer tube. After the assembly, the tool switches off 
automatically and can be removed from the tube joining.

 

 

 

Powered by PageSpeed